Home > Variable Frequency Drives
Three phase, 380V ± 20%, 0.75 to 2.2kW
ZVF9V-M Mini Type vector control VFD
Input Voltage(V) | Output Voltage (V) | Power Range (kW) |
Single phase 220V± 20% | Three phase 0~input voltage | 0.75kW~2.2kW |
Three phase 380V± 20% | Three phase 0~input voltage | 0.75kW~2.2kW |
Overload Capacity : 150% 1 minute ;180% 1 second ;200% transient protection . |
Technical Indications :
1.Control Mode: SAPWM vector control .
2.Output Frequency range: 0.00~400.00HZ
3.Operation command selection : Keyboard control ,Terminal Control, Multi-stage control , External analog voltage input control . External analog current input control .RS485 control .
4.Frequency setting Mode: Digit keypad setting, Analog setting ( current , voltage signal ). Remote communication setting , Multi-step speed setting. Terminal assembled setting . PID closed-loop setting.
5.Start torque control :0-20% can be adjusted .
6.Carrier frequency range:1.0K~15KHz
7.DC current braking : Start and stop DC current braking can be adjusted solely .
8. Automatism voltage Modulate : ( AVR): Automatically keep output voltage stable when input voltage fluctuation .
9.Automatic limiting current : can limit the Maximum current of the motor. And can protect the inverter and the motor reliably.
10. PLC programmable control: Single Cycle, continuous loop, wobble control and are suitable for all kinds of applications
11.Input ,output terminal are programmable and It’s convenient for user.
12.Analog signals output , voltage and current can be selected .
Item
Item Description
Input
Rated voltage frequency
Single/three-phase 220VAC,three-phase 380VAC,50Hz/60Hz
Allowable voltage range
Voltage fluctuation range:-20%~+20%
Output
Rated voltage
Three-phase 0~input voltage VAC
Frequency
0.00~400.00Hz
Overload capacity
Type G:150% 1 minute; 180% 1 second;200% transient protection
Control function
Modulation
Optimal space voltage vector PWM modulation
Control method
Speed sensorless vector control (SVC)
Frequency accuracy
Digital setting: Max. frequency ×±0.01%
Frequency resolution
Digital setting:0.01Hz Analog setting; Max. Frequency ×0.1%
Starting frequency
0.00~10.00Hz
Torque lifting
Automatic torque lifting: To lift the torque automatically
Slip compensation
Setting range:0~150%.The inverter output frequency can be auto-
Acceleration/deceleration
0.1~3600.0 sec/min ,which can be set in sequence
Carrier frequency
1.0~15.0KHz
Jog function
Jog frequency range:0.01~400.0Hz Jog acceleration/deceleration
V/F curve
1.linear curve; 2.quadratic curve(conic); 3.User defined V/F curve
Control Function
Automatic
Auto optimize V/F curve according to load fluctuation
Auto voltage
When the network voltage changes, it can regulate
Built-in PID
This can form a convenient closed-loop control system
Operating function
Operating command
Operator panel control ,external terminal control and COM control
DC braking
Panel potentiometer setting, operator panel ▲▼ setting, external
Input Signal
Forward/Reverse signal, multiple speed signal, failure signal,
Output signal
Programmable relay, open-collector output, failure signal output and etc.
Multi-function analog
This can realize the output of frequency, current and other physical
Braking function
Dynamic braking
With an external braking resistor, the maximum braking
DC braking
This can be selected when the motor starts or stops with the
Other functions
Leap frequency, Jog function, counter to rotating speed, instant
Protection function
Input open-phase protection, over-current protection,
Inverter Model
Voltage
(V)
Power
(KW)
Current
( A)
Dimension (mm)
H
W
A
B
D
d
ZVF9V-M0007S2
220V
0.75
4.0
151.0
100
140.0
89.5
116.5
Ф5
ZVF9V-M0015S2
1.5
7.5
151.0
100
140.0
89.5
116.5
Ф5
ZVF9V-M0022S2
2.2
10
151.0
100
140.0
89.5
116.5
Ф5
ZVF9V-M0007T4S
380V
0.75
2.3
151.0
100
140.0
89.5
116.5
Ф5
ZVF9V-M0015T4S
1.5
3.7
151.0
100
140.0
89.5
116.5
Ф5
ZVF9V-M0022T4S
2.2
5.0
151.0
100
140.0
89.5
116.5
Ф5
Voltage unbalance rate<3%;frequency fluctuation≤±5%
Analog setting:Max.Frequency×±0.2%
According to the output current.
Hand-operated torque lifting: Range: 0.1~30.0%
Regulated within this range according to the motor load so as to reduce
The speed variation of the motor due to load fluctuation
Time
Time,0.1~3600.0 can be set
energy-saving
operation
To realize energy-saving operation.
regulation (AVR)
PWM output automatically to maintain constant voltage.
(CLCS),and is applicable to pressure control, flow
control and other process control.
Terminal up/down setting, analog voltage signal or external potentiometer
Setting, analog current signal setting, analog assembly setting,485 COM
Setting and etc
reset signal and etc.
and digital output
terminal
quantity by outputting 0~20mA DC signal and 0~10KHz
digital signal
torque may reach 100% .
Action frequency of 0~30 sec., which can be set in sequence
shutdown restarting, Frequency upper/lower limitation, acceleration/
deceleration mode regulating, frequency meter and voltmeter output,
multiple speed/program operation, two-wire/three wire control,
vibration frequency control, Multi-function input terminal selection,
Failure auto reset and 485COM.
overload protection, under voltage protection,
overheating protection and etc.